Meanwell Rectifier Module NMP650 NMP1K2 NMS-240-5/12/24/48 NMS-240-24 650W 1200W Power Supply
Mean Well Rectifier Module NMP650 NMP1K2 650W Rectifier Module
Wattage :
650W/1200W
Features :
Medical (2x MOPP) ITE safety approvals
Suitable for BF application with appropriate system consideration (Touch current < 100uA/264VAC)
1U low profile
Built-in parallel function / output programmable / global enable / remote local ON-OFF / auxiliary DC output / over temperature alarm / DC OK
Cooling by thermostatically controlled fan with fan alarm function
5 years warranty
Model
NMP650 NMP1K2
Technical
MODEL | NMP650 (4 Slots) | NMP1K2 (6 Slots) |
INPUT | VOLTAGE RANGE Note.6 | 90 ~ 264VAC 120 ~370VDC |
FREQUENCY RANGE | 47 ~ 63Hz |
POWER FACTOR | PF>0.95/230VAC PF>0.98/115VAC at full load |
EFFICIENCY(Typ.) Note.4 | 91%, full case load with H / K module at nominal 24V / 48V only | 90.5%, full case load with H / K module at nominal 24V / 48V only |
88.5%, full case load with each type of module at nominal voltage |
AC CURRENT | 3.5A/230VAC 7.5A/115VAC | 6.7A/230VAC 13.5A/115VAC |
INRUSH CURRENT | 40A/230VAC 25A/115VAC | 40A/230VAC 25A/115VAC |
LEAKAGE CURRENT | Earth leakage current <400uA / 264VAC, Touch current <100uA/264VAC |
OUTPUT | TOTAL OUTPUT POWER | 650W max. | 1200W max. |
PROTECTION | OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down |
FUNCTION | REMOTE CONTROL | RC+/RC-: Short, Power ON RC+/RC-: Open, Power OFF |
ALARM SIGNAL | TTL signal output for over temperature alarm. Please refer to the Function Manual. |
AUXILIARY POWER(AUX) | 5V @ 1.5A ; tolerance ±10%; ripple: 50mVp-p (max.) | 5V @ 2A; tolerance ±10%; ripple: 50mVp-p(max.) |
ENVIRONMENT | WORKING TEMP. | -30 ~ +70℃ (Derate at 50℃, refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY | -40 ~ +85℃, 10 ~ 95% RH non-condensing |
TEMP. COEFFICIENT | ±0.03%/℃ (0 ~ 50℃) |
VIBRATION | 10~500Hz, 2G 10min./1 cycle, 60 min. each along X, Y, Z axes. |
SAFETY & EMC (Note 5) |
SAFETY STANDARDS | ANSI/AAMI ES60601-1, Ed. 3.1,UL62368-1; TUV BS EN/EN60601-1, Ed. 3.1, TUV BS EN/EN62368-1; IEC 60601-1, Ed. 3.1, IEC 62368-1, IEC60950-1; EAC TP TC 004 approved |
ISOLATION LEVEL | Primary-Secondary: 2x MOPP, Primary-Earth: 1x MOPP |
WITHSTAND VOLTAGE | I/P-O/P: 4KVAC I/P-FG: 2KVAC O/P-FG: 0.5KVAC |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC / 25℃/ 70% RH |
EMC EMISSION | Parameter | Standard | Test Level / Note |
Conducted | BS EN/EN55032 (CISPR32) / BS EN/EN55011 (CISPR11) | Class B |
Radiated | BS EN/EN55032 (CISPR32) / BS EN/EN55011 (CISPR11) | Class B |
Harmonic Current | BS EN/EN61000-3-2 | Class A |
Voltage Flicker | BS EN/EN61000-3-3 | ----- |
EMC IMMUNITY | BS EN/EN60601-1-2, BS EN/EN55024, SEMI F47 |
Parameter | Standard | Test Level / Note |
ESD | BS EN/EN61000-4-2 | Level 4, 15KV air; Level 4, 8KV contact |
RF field | BS EN/EN61000-4-3 | Level 3, 10V/m |
EFT/ Burst | BS EN/EN61000-4-4 | Level 3, 2KV |
Surge | BS EN/EN61000-4-5 | Level 4, 4KV/Line-FG; 2KV/Line-Line |
Conducted | BS EN/EN61000-4-6 | Level 2, 3V |
Magnetic Field | BS EN/EN61000-4-8 | Level 4, 30A/m |
Voltage Dips and Interruptions |
BS EN/EN61000-4-11 | 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods |
OTHERS | MTBF | 1314.6K hrs min. Telcordia SR-332 (Bellcore) ; 128.2K hrs min. MIL-HDBK-217F (25℃) (NMP650) 1275.4K hrs min. Telcordia SR-332 (Bellcore) ; 124.5K hrs min. MIL-HDBK-217F (25℃) (NMP1K2) |
DIMENSION | 250*89*41mm (L*W*H) | 250*127*41mm (L*W*H) |
PACKING | 1.45Kg (typ.); 9pcs / 14Kg / 0.98CUFT | 2Kg (typ.); 6pcs / 13Kg / 0.88CUFT |






Solutions
We deliver end-to-end telecommunications solutions, encompassing site audits, customized planning aligned with client specifications, round-the-clock technical assistance, and proactive maintenance—both domestically and internationally. Our global network of certified partners and in-house experts ensures seamless execution
FAQ :
1.Q: How does your company handle quality issues statistically?
A: Over the past 10 years, our quality issue resolution rate is 99.5%. When a quality problem occurs, we initiate a 7 - step investigation process. If it's our fault, we resolve 90% of issues within 2 business days, as per our historical data. Our service team responds to all quality - related inquiries within 2 hours on average.
2.Q: What are the quality metrics for your products?
A: All products are 100% original and newly packaged. Our pre - shipment testing ensures that product defect rates are less than 0.05%. Each item undergoes at least 3 quality checks before being dispatched, guaranteeing high - quality output.
3.Q: What's the data - backed reliability of the 1 - year guarantee?
A: In the past year, only 0.3% of products under the 1 - year guarantee required service. Of those, 95% of issues were resolved within the first month. Our data shows that our products have a high reliability rate, and we stand firmly behind our 1 - year quality guarantee.
4.Q: What's the process and data for handling inferior - quality goods?
A: For products within the 1 - year guarantee period, we have a 100% replacement policy. The average time from receiving a complaint about a bad product to sending out a replacement is 24 hours. We cover all return shipping costs, ensuring a seamless experience for our customers.